+91 98240 10980 admin@ellfordimpex.com
Free Consulting

Fuji Chemical

Technical Product Specifications

Detailed processing parameters for RA-4 Digital Minilabs

Combo Pack Bottles
Content : P1-1 Ltr., P2-2 Ltr.
P1 R Bleach Fix Replenisher
9 Ltr + 1Bottle = 10 Ltr
+ = 10 Ltr

Working Tank Solution
(Mother Tank)
+ Repl + Repl
450 ml550 ml50 ml
450 ml550 ml
P2 R Developer Replenisher
8 Ltr + 1Bottle = 10 Ltr
+ = 10 Ltr

Working Tank Solution
(Mother Tank)
+ Repl + Repl
450 ml600 ml
450 ml600 ml

COMBO Pack 90

P1 – R    P2 – R
Process Specification

Recommended Time
MIN : SEC
0 : 45
Temperature C
 
36 ÷ 38.5
Replenishment Rate
Repl Rate (M²)
90 ml
Cartridge Chemistry

EL -49 LR PC

Cartridge Chemistry
PACKING :
  • 2 X 2 pc
  • 2 X 111 m X 2 (sq mtr)
Process Specifications for Frontier 340, 350, 550 & 570
Machine Process Time (sec.) Temp C Repl Rate (ml/m2)
Frontier
550, 570
Dev P1 19 43 45
B/Fix P2 19 41 35
Frontier
7500/7600
Dev P1 19 43 45
B/Fix P2 19 41 35